24/7 Emergency Fire Safety Support 1-800-FIRE-911

Complete Fire Safety Product Range

Explore our certified fire protection equipment designed to meet the highest safety standards — from detection and suppression to emergency lighting and signage.

Detection & Alarm Suppression Systems Fire Extinguishers Hoses & Cabinets Safety Signage Emergency Lighting

Fire Detection & Alarm Systems

Intelligent detection solutions — UL 864 & EN 54-2 compliant systems for early warning and rapid response

Addressable Fire Alarm Control Panels

Intelligent addressable panels providing precise zone-by-zone detection and control. Supports up to 512 devices per loop with full fault monitoring, event logging, and intuitive LCD display interface.

UL 864 EN 54-2 NFPA 72

Conventional Fire Alarm Panels

Cost-effective conventional fire alarm control panels suitable for smaller buildings and zones. Zone-based detection with clear LED indicators, audible/visual alarm outputs, and relay outputs for integration.

UL 864 EN 54-2 BIS

Optical Smoke Detectors

Photoelectric principle detectors with superior sensitivity to smoldering fires and slow-burning materials. Wide-angle coverage, 360° detection, and minimal false alarm rates suitable for offices and homes.

EN 54-7 UL 268 NFPA 72

Ionization Smoke Detectors

Dual-chamber ionization technology for fast-flaming fire detection. Highly responsive to invisible combustion particles, ideal for commercial kitchens, warehouses, and high-airflow environments.

EN 54-7 UL 268

Fixed Temperature & Rate-of-Rise Heat Detectors

Dual-function heat detectors that activate on fixed temperature threshold (57°C/68°C) or rapid temperature rise. Perfect for dusty, smoky, or high-humidity environments where smoke detectors may cause false alarms.

EN 54-5 UL 521

Flame Detectors

UV/IR and multi-spectrum flame detectors for rapid flame detection within milliseconds. Ideal for high-risk industrial environments including petrochemical plants, warehouses, and aircraft hangars.

EN 54-10 FM Approved

Manual Call Points (Break Glass)

Manual fire alarm activation points — both break glass and push-button types. Weatherproof options available for outdoor use. Resettable with key to minimize vandalism. Clear visual indicator after activation.

EN 54-11 UL 38

Wireless Fire Detection Systems

Radio frequency wireless detection systems ideal for heritage buildings, retrofits, and locations where cabling is impractical. Bi-directional communication with full supervision and tamper detection.

EN 54-25 NFPA 72

Building Management System (BMS) Integration

Fire alarm integration with building management systems via BACnet, Modbus, and SNMP protocols. Enable centralized monitoring, automated HVAC shutdown, elevator recall, and access control during fire events.

BACnet Modbus NFPA 72

Fire Suppression Systems

Advanced suppression solutions — NFPA 13, NFPA 17A & NFPA 2001 compliant for all hazard levels

Wet Pipe Sprinkler Systems

The most common and reliable suppression system — water-filled pipes connected to sprinkler heads that activate individually at the fire source. Suitable for heated spaces where pipes won't freeze.

NFPA 13 EN 12845 FM Approved

Dry Pipe Sprinkler Systems

Air or nitrogen-pressurized pipes for use in unheated spaces, cold storage, and parking structures. Prevents freezing damage to pipes while maintaining fire suppression readiness year-round.

NFPA 13 EN 12845

Pre-Action Sprinkler Systems

Two-signal activation system combining a detection event with sprinkler head activation. Ideal for data centers, museums, and archival storage where accidental discharge could cause catastrophic damage.

NFPA 13 FM Approved

Deluge Sprinkler Systems

All sprinkler heads open simultaneously — activated by fire detection signal. Provides rapid total coverage for high-hazard environments like aircraft hangars, chemical plants, and flammable liquid storage.

NFPA 13 NFPA 16 FM

FM-200 (HFC-227ea) Clean Agent Systems

Fast-acting gaseous suppression agent that extinguishes fire without water, residue, or damage to sensitive equipment. Response within 10 seconds. Safe for occupied spaces. Ideal for server rooms and archives.

NFPA 2001 ISO 14520 UL 2166

Novec 1230 Clean Agent Systems

Environmentally sustainable clean agent with zero ozone depletion potential. Ultra-fast suppression in under 10 seconds. No electrical conductivity — safe for energized equipment. Ideal for critical facilities.

NFPA 2001 ISO 14520 FM Approved

CO2 Suppression Systems

High & low pressure CO2 systems for industrial machinery, printing presses, and electrical equipment fires. Total flooding or local application. Requires evacuation — not suitable for normally occupied spaces.

NFPA 12 ISO 6183

AFFF Foam Suppression Systems

Aqueous Film Forming Foam (AFFF) and AR-AFFF systems for Class B flammable liquid fires. Foam monitors, bladder tanks, and proportioning systems for petroleum storage, loading racks, and helidecks.

NFPA 11 NFPA 16 FM

Kitchen Hood Suppression Systems

UL 300 compliant automatic wet chemical suppression systems for commercial kitchen cooking appliances. Simultaneous fuel/gas shutoff and suppression discharge. Mandatory for all commercial kitchens per NFPA 96.

UL 300 NFPA 17A NFPA 96

Fire Extinguishers

Portable and wheeled extinguisher equipment for all fire classes — UL Listed, EN 3, and NFPA 10 compliant

ABC Dry Chemical Powder Extinguishers

Multi-purpose portable extinguishers effective on Class A (ordinary combustibles), B (flammable liquids), and C (electrical) fires. Available in 1kg to 50kg capacities. Ideal for offices, homes, and factories.

NFPA 10 UL Listed EN 3 BIS

CO2 Fire Extinguishers

Clean, residue-free carbon dioxide extinguishers for Class B and electrical fires. Safe for use on sensitive electronic equipment, server rooms, and laboratories. Available in 2kg to 10kg capacities.

NFPA 10 UL Listed EN 3

Water & Water Additive Extinguishers

Effective for Class A fires (wood, paper, fabric). Water additive types provide enhanced cooling and penetrating action. Environmentally safe — no chemical residue. Suitable for indoor Class A fire risks.

NFPA 10 EN 3

Foam (AFFF) Extinguishers

Aqueous Film Forming Foam extinguishers for Class A and B fires. Form a cooling foam blanket over liquid fires to prevent re-ignition. Suitable for fuel storage areas, garages, and industrial facilities.

NFPA 10 EN 3 UL Listed

Class K Wet Chemical Extinguishers

Specially formulated wet chemical extinguishers for Class K cooking oil and fat fires. Mandatory for commercial kitchens. Saponification reaction creates a foam blanket preventing re-ignition. UL 300 rated.

UL 300 NFPA 10 NFPA 17A

Wheeled Industrial Extinguishers

Heavy-duty wheeled extinguishers in 25kg to 250kg capacities for industrial applications, construction sites, aircraft hangars, and large-scale fire risks requiring higher discharge volume and range.

NFPA 10 UL Listed FM Approved

Fire Hoses, Cabinets & Hydrants

Complete hose and hydrant solutions — EN 671-1, NFPA 24 & BS 750 compliant systems

Manual Swing-Type Hose Reels

Traditional manual hose reels with 25mm semi-rigid hose and spray/jet nozzle. Swing-out design for maximum reach in all directions. Easy operation by untrained personnel. For light hazard occupancies.

EN 671-1 NFPA 14 BIS

Automatic Hose Reels

Self-retracting automatic hose reels that automatically retract after use. Spring-loaded mechanism ensures tidy storage. Available with various hose lengths and nozzle configurations for different hazard levels.

EN 671-1 NFPA 14

Steel & Stainless Steel Fire Cabinets

Powder-coated steel and stainless steel fire hose cabinets in various sizes. Recessed, semi-recessed, and surface-mount options. Glass fronted or solid door designs. Custom sizes available on request.

EN 671-1 NFPA 14

Pillar & Underground Hydrants

Single and twin-outlet pillar fire hydrants and underground box hydrants for outdoor fire fighting operations. Includes breeching inlets, standpipes, and associated fittings for municipal and industrial use.

BS 750 NFPA 24 BIS

Landing Valves & Inlet Connectors

Angle pattern and in-line landing valves for wet and dry riser systems. Various inlet and outlet sizes (63mm/65mm). Breeching inlets for fire brigade use. Compliant with Indian fire brigade standards.

NFPA 14 BIS

Lay-Flat Hoses, Nozzles & Accessories

High-pressure lay-flat fire hoses (40mm, 65mm), combination spray/jet nozzles, hose couplings, branch pipes, dividing breeching, and collecting heads. Complete range of fire hose accessories and spare parts.

NFPA 1961 BIS

Fire Blankets

Fiberglass fire blankets for smothering small fires and protecting personnel during evacuation. Quick-release wall-mounted storage cases. Available in 1m x 1m to 1.8m x 1.2m sizes. Kitchen and industrial grades.

EN 1869 NFPA 10

Safety Signage & Markings

Evacuation and safety signage — ISO 7010, EN 7010, and photoluminescent standards compliant

Photoluminescent Safety Signs

Glow-in-the-dark photoluminescent fire exit, directional, and safety signs. Charge from ambient light — visible for up to 8+ hours in total darkness. No power required. Perfect for power failure situations.

ISO 7010 EN 7010 BS 5499

LED-Illuminated Safety Signs

Internally illuminated LED exit and safety signs with long-life LED technology (50,000+ hours). Maintained and non-maintained versions available. Battery backup ensures operation during power failure.

ISO 7010 EN 60598 UL 924

Evacuation Route Maps & Floor Plans

Custom-designed and printed evacuation route maps, floor plans, and assembly point notices. Compliant with fire safety legislation. Regular updates available as building layouts change. Framed and unframed options.

ISO 7010 NFPA 101

Floor Safety Markings & Tapes

Anti-slip photoluminescent floor marking tapes for stairways, aisles, and evacuation routes. High-visibility in both normal and emergency lighting conditions. Chemical and abrasion resistant for industrial use.

ISO 7010 EN 13501

Fire Equipment Location Signs

Directional signs indicating location of fire extinguishers, fire alarms, hose reels, and assembly points. Available in rigid board, brushed aluminum, and photoluminescent materials. Custom text and symbols.

ISO 7010 NFPA 170

Voice Evacuation Signage Panels

Combined visual and audible emergency communication panels with integrated LED indicators and voice evacuation messages. For large buildings requiring coordinated multi-zone evacuation. BMS integration ready.

EN 54-16 NFPA 72

Emergency Lighting Systems

Life-safety emergency and exit lighting — UL 924, EN 1838 & NFPA 101 compliant systems

LED Emergency Exit Lights

Energy-efficient LED emergency exit luminaires with built-in battery backup (1-3 hour operation). Self-testing models available with automatic monthly and annual test functions. Slim profile recessed and surface designs.

UL 924 EN 1838 NFPA 101

LED Emergency Downlights & Bulkheads

Emergency downlights and bulkhead luminaires for corridor and stairway emergency escape route illumination. Maintained and non-maintained options. 3-hour emergency duration with deep-discharge protection.

UL 924 EN 60598

Central Battery Systems

Centralized emergency battery power supply systems for large-scale emergency lighting networks. Modular design for easy expansion. Remote monitoring and self-test reporting via dedicated monitoring software.

EN 50171 UL 924

Self-Testing Emergency Lighting

Automated self-testing emergency luminaires that perform regular functional tests and report results via wireless mesh network. Eliminates need for manual testing. Automatic reporting of failures with location.

EN 62034 NFPA 101

Voice Evacuation Systems

Integrated voice evacuation and public address systems compliant with EN 54-16. Pre-recorded and live announcement capability. Zoned evacuation messages for large buildings. PA system integration for daily use.

EN 54-16 NFPA 72 IEC 60849

Emergency Lighting Monitoring Software

Web-based and desktop monitoring platform for complete emergency lighting system management. Real-time status dashboards, automatic test scheduling, failure alerts, and compliance reports for facility managers.

EN 62034 BS 5266

Need Help Choosing the Right Products?

Our certified fire safety engineers will assess your requirements and recommend the best solutions for your facility.